Do not use 1 4 usg durock cement board for wall or ceiling applications.
Stc concrete board wall.
Maximum installed weight of the finish system should not exceed 15 psf.
Insulation will noticeably improve the stc rating of an assembly.
The stc ratings for masonry walls also can be improved by filling the cores of hollow units with sand or creating a cavity wall.
With 1 25 mm type s drywall screws 12 305 mm o c.
Plaster board on one side and 1 layer of 16mm on the other side on a horizontal flexible channel at 600mm 2ft centres screwed to the stud.
While effective for high stc the two walls take additional floor space and have a higher material cost than single stud construction.
Determining sound transmission class stc for concrete masonry.
Staggered or double stud walls are higher rated than single stud walls.
In the us it is widely used to rate interior partitions ceilings floors doors windows and exterior wall configurations.
Do not use usg durock cement board with vinyl flooring.
8 concrete block hollow core painted 2 coats 2 sides.
Gypsum board each side provides stc 63 and a wall footprint 10 3 4 in deep.
Standard stud wall with one layer of 16mm 5 8 plasterboard.
Attaching gypsum board to a masonry wall with resilient clips can increase the stc rating by 12 to 15 points ref.
8 concrete block hollow core no wall finish.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
To view different wall assemblies click on each point below that may apply to your project.
Metal stud walls perform better than wood stud walls.
Double 2 x 4 stud wall with two layers of 5 8 in.
T h e r e c o m m e n d e d s t c o f a wall is the numerical difference between two sound levels.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panels applied perpendicular to rigid furring channels 24 610 mm o c.
Sound transmission class or stc is an integer rating of how well a building partition attenuates airborne sound.
Gypsum board end joints located midway between continuous channels and attached to additional pieces of channel 54 1372 mm long with screws at 12 305.
Stc ratings for wall floor and window materials and assemblies 3 appendix a stc ratings a 1 walls a 1 exterior a 1 interior a 9 wooden studs a 9 metal studs a 14 floors a 16 wood a 16 concrete a 21 windows a 24 doors a 27 exterior a 27 interior a 29 appendix b references b 1.
Usg durock cement board is not designed for use as a structural panel.