A 0 to 400 cfm fan requires a 4 inch minimum duct size but a 6 inch duct is recommended.
Standard rectangular duct sizes.
Download free duct sizing chart pdf according to ashrae standard.
The rectangular dimensions and the air flow volume are adapted to the equal friction loss.
Use insulated duct or duct board in unheated spaces.
Sealant is available in the seams upon request.
Rectangular ductwork is manufactured in three different styles.
Equivalent diameter rectangular and circular hvac ducts equivalent diameter for rectangular and circular ducts air flows between 100 50000 cfm maximum size of duct or pipe through steel joists k series joists and maximum size of ducts and pipes.
These duct chart are based on equal friction method with a friction loss value 0 1 inch 100ft.
Flexible duct work must be stretched tightly for maximum air flow.
Master flow 24 in.
Galvanized steel flat sheet can be cut to size for a tough hvac job that requires a customized fitting.
Last take off run to be located 12 18 from end.
The table below can be used to compare equivalent diameters for rectangular and round circular ducts.
Never locate ducts at the end of the trunk line run.
The master flow 36 in.
They are as follows.
All ductwork comes standard with stiffening beads.
Duct work is otherwise called as duct system.
The minimum duct sizes and recommended duct sizes based on a hood fan s cfm rating are as follows.
Rectangular or square ducting comes in standard sizes ranging from 3 by 7 inches to 35 by 40 inches.
The equivalent diameter is the diameter of a circular duct or pipe that gives the same pressure loss as an equivalent rectangular duct or pipe.
Wrap around duct l shape duct all sizes shall be listed using outside.
The hvac model that you re interested in should offer information regarding the maximum airflow per cubic foot per minute or cfm to help you determine adequate.
The table is based on the ducts friction loss formula.
Duct size chart calculate duct dimensions for both rectangular and round ducts.
For screen reader problems with this website please call 1 800 430 3376 or text 38698 standard carrier rates apply to.
Sizing is based on airflow needs per cubic foot per minute as well as velocity.
Provided here is the rectangular duct sizes chart for your personal reference and this chart table shows the duct size cfm and their equivalent diameter in inches.
The length of the rectangular duct size would range from 0 7mm to 0 9mm galvanised mild steel depending on size.
Half section rectangular duct model rd24x8x48.
Always stagger take off ducts by 12 to maintain pressure.